noxsystems
     
   

NOX SYSTEM - Central Unit

All the information is gathered together in the central unit. It collects the individual pieces of information from the modules, assesses them, logs changes and triggers the corresponding alarms. The connections to the operating devices and the modules are based on the NOX Bus. Only one cabling for burglary, fire detection, access controls and building control is needed. The functions are software-based, keeping them open for further expansion. With the Ethernet TCP/IP connection it is possible to configure and communicate with other applications.

The codes and authorisations are managed from the central unit. The individual alarms and sensors are configured via the central unit. By installing alarm transmission units, alarms are forwarded to the police or a security company. These devices can be connected using a standard interface to the central unit.

The integrated uninterruptable power supply bridges power outages. As a result, the entire security system functions without interruption. As protection against damage and sabotage, the casing of the central unit is fitted with an electronic anti-drilling protection.

CONNECTION CAPACITY


Detectros
4'000
Each alarm with its own profile, delay times and sabotage alarm.
Areas
800
Individually operable areas. Any number of definable area groups for simple system operation.
Personal code
10’000
In addition to the personal code, the user profile, user language, an access code with a PIN number and a duress notification code can be stored by each user.
Blocking time areas
800
Freely definable blocking times with separate holiday management, which can be used for automatic arming and disarming areas.
Log entries
10’000
Alarm reports and user actions each in a separate cyclical log.
Devices (standard/max.)
600/1’800
Number of devices such as operator elements, input and output units, card reader, temperature sensors etc., which can be connected to a central unit.
Integrated Bus connections
3
1’200 m cabling per Bus, expandable with repeaters. Uses a 4-wire cable (without shielding).
Expandable Bus connections
6
Connectable via TCP/IP network each with up to 200 additional devices per Bus.
 
 
NOX CONFIG
User-friendly software for configuring and servicing the entire NOX system.